Services
Equipment Loans List:
Equipment | LaPlaza | EAX | Total | Comments |
---|---|---|---|---|
RP 2300 Speciation Sampler | 2 | 0 | 2 | This is a multi-channel PM 2.5 sampler (non-FRM). It will collect a sample on various media and will allow a laboratory to study the various components of the PM 2.5 sample that is collected. The TAMS Center gravimetric lab does not have the capability to provide speciation analyses. |
RP 2000H Single Channel | 2 | 5 | 7 | Single channel FRM PM 2.5 sampler. |
RP 2025 Sequential Sampler | 0 | 2 | 2 | This is a 3 channel gravimetric PM 2.5 sampler. The filters used are the same filters utilized by the FRM PM 2.5 samplers. |
TEOM | 0 | 2 | 2 | This unit is manufactured by the R&P company and is a continuous PM 2.5 sampler. This unit includes the sampler and the environmentally conditioned housing for the sampler. |
Anderson Sequential Sampler | 0 | 2 | 2 | This is a multi-channel PM 2.5 sampler that utlizes the same filters as the FRM PM 2.5 samplers. |
Anderson RAAS Single Channel | 3 | 2 | 5 | This is an FRM PM 2.5 sampler made by the Anderson company. |
Met One Multi-Channel | 0 | 1 | 1 | This is a multi-channel PM 2.5 sampler that utilizes the same filters as those used in the FRM PM 2.5 samplers. |
Anderson PM 10 Sampler (old style) | 1 | 0 | 1 | Old model PM 10 sampler that uses the large filters. |
AirMetrics Mini-Vol | 0 | 0 | 0 | PM samplers used for saturation style sampling. These samplers are not FRM although support for these samplers can be obtained from the TAMS Center gravimetric laboratory assuming that the lab has capacity to do so. |
Environics 6100 Calibrator | 0 | 1 | 1 | This unit is typically used to mix gases in the calibration or calibration check of gaseous pollutant samplers (for example Nox ro SO2 samplers). |
ESC 8816 Datalogger | 0 | 1 | 1 | General datalogger. |
API 200 AU NOx | 1 | 1 | 2 | Gaseous pollutant continuous sampler for Nox. |
Thermo 43C SO2 | 0 | 1 | 1 | Gaseous pollutant continuous sampler for SO2. |
Teledyne 701 Zero Air | 0 | 1 | 1 | Unit designed to provide zero air to gaseous pollutant samplers. This unit provides up to 20 liters/min of zero air. Zero air is provided by internal filration of ambient air. |
API O3 Calibrator 401 | 0 | 1 | 1 | Gaseous pollutant sampler for ozone. This unit has the capability to produce and measure ozone. |
Teledyne 400E O3 | 0 | 2 | 2 | Gaseous pollutant sampler for ozone. This unit has the capability to produce and measure ozone. |
API Zero Air 701 | 1 | 0 | 1 | Unit designed to provide zero air to gaseous pollutant samplers. This unit provides up to 20 liters/min of zero air. Zero air is provided by internal filration of ambient air. |
Teledyne 300 EU CO | 1 | 0 | 1 | Gaseous pollutant sampler designed for carbon monoxide. This unit was originally designed as a trace gas sampler but it operates exactly like the units currently used for gaseous pollutant sampling. |
Andersen Calibration Kits | 4 | 0 | 5 | Calibration kits that are designed to be used with the Anderson PM 2.5 FRMs. |
Delta Cal | 3 | 0 | 3 | These units provide the ability to measure flowrate and are normally used in the calibration check of FRM PM 2.5 samplers. |
Dry Cal Lite | 2 | 0 | 3 | These units provide the ability to measure flowrate and are normally used in the calibration check of FRM PM 2.5 samplers. |
Chinook Engineering FTS | 11 | 0 | 11 | These units provide the ability to measure flowrate and are normally used in the calibration check of FRM PM 2.5 samplers. |
Digital Thermometer | 17 | 0 | 17 | |
Druck Barometer | 13 | 0 | 13 | Used to measure pressure and it typically used in the calibration check of PM samplers. |
Indoor CO Analyzer (Bacharach Monoxor III) | 1 | 0 | 1 | Indoor environmental air quality monitor for CO. This is to be used as an investigative tool only. |
Moisture Check Device & Computer Interface | 1 | 0 | 1 | This is an investigative tool designed to measure moisture in building walls. |
Fluke Infrared Thermometer | 1 | 0 | 1 | This is a thermal camera that is used to find hot and/or cold spots in a room. Typically, this camera is used in conjunction with a blower door when investigating the building tightness of a particular house. |
Sling Psychrometer | 1 | 0 | 1 | A relative humidity calibratior. |
MetOne Particle Counter | 1 | 0 | 1 | An investigative tool designed to measure inhalable particles in a variety of ranges. This tool is designed for indoor use. |
Gravimetric PM 10 and PM 10 samplers | 14 | 0 | 14 | Samplers that are designed to be operated indoors. Pumping units are sound protected to limit amount of sound produced during sampling. Filter based and would required gravimetric laboratory support. Units samples at 10 to 20 liters per minute and are typically deployed for 8 hours or more. These samplers are that FRM nor are they FEM samplers. |